SOLID STATE SOFT STARTER For 3-phase applications 1HP- 30HP 3A-30A
|
|
1-972-699-9976 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SOFT STARTS (3-phase application, 2 phases controlled |
|
|||||||||
|
|
Standard Models |
|
Line voltage VAC |
Motor Load FLA |
|
UL HP Ratings |
|
Control Voltage VAC/DC |
Module mm |
Dimensions |
|
|
|
SMC 3 DA 2303 |
|
208-240 |
3A |
|
1 |
|
24-240 |
22.5 |
94 X 123.1 X 22.5 |
|
|
|
SMC 3 DA 2315 |
|
208-240 |
15A |
|
5.5 |
|
24-240 |
45 |
94 X 128.1 X 45 |
|
|
|
SMC 3 DA 2325 |
|
208-240 |
25A |
|
10 |
|
24-240 |
90 |
94 X 128.1 x 90 |
|
|
|
SMC 3 DA 4803 |
|
440-480 |
3A |
|
2 |
|
24-480 |
22.5 |
94 X 123.1 X 22.5 |
|
|
|
SMC 3 DA 4015 |
|
440-480 |
15A |
|
10 |
|
24-480 |
45 |
94 X 128.1 X 45 |
|
|
|
SMC 3 DA 4025 |
|
440-480 |
25A |
|
15 |
|
24-480 |
90 |
94 X 128.1 x 90 |
|
|
|
SMC 3 DA 6003 |
|
500-600 |
3A |
|
2 |
|
24-480 |
22.5 |
94 X 123.1 X 22.5 |
|
|
|
SMC 3 DA 6015 |
|
500-600 |
15A |
|
10 |
|
24-480 |
45 |
94 X 128.1 X 45 |
|
|
|
SMC 3 DA 6025 |
|
500-600 |
25A |
|
25 |
|
24-480 |
90 |
94 X 128.1 x 90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SOFT STARTS (3-phase application, 2 phases controlled |
|
|||||||||
|
|
Bypass versions with Aux. Contacts |
|
Line voltage VAC |
Motor Load FLA |
UL HP Ratings |
Control Voltage VAC/DC |
Module mm |
Dimensions |
|
||
|
|
|
|
|
w/o bypass |
w/ bypass |
w/o bypass |
w/ bypass |
|
|
|
|
|
|
SMC 3 DA 2325 BP |
|
208-240 |
25A |
30A |
10 |
10 |
24-240 |
90 |
94 X 128.1 x 90 |
|
|
|
SMC 3 DA 4025 BP |
|
440-480 |
25A |
30A |
15 |
20 |
24-480 |
90 |
94 X 128.1 x 90 |
|
|
|
SMC 3 DA 6025 BP |
|
500-600 |
25A |
30A |
25 |
30 |
24-480 |
90 |
94 X 128.1 x 90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SOFT STARTS (3-phase application, 3 phases controlled |
|
|||||||||
|
|
Bypass versions with Aux. Contacts |
|
Line voltage VAC |
Motor Load FLA |
UL HP Ratings |
Control Voltage VAC/DC |
Module mm |
Dimensions |
|
||
|
|
|
|
|
w/o bypass |
w/ bypass |
w/o bypass |
w/ bypass |
|
|
|
|
|
|
SMC 3 DA 2325 BP |
|
208-240 |
17A |
25A |
5 |
10 |
24-240 |
90 |
94 X 128.1 x 90 |
|
|
|
SMC 3 DA 4025 BP |
|
440-480 |
17A |
25A |
10 |
20 |
24-480 |
90 |
94 X 128.1 x 90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Technical Specifications |
|
|
||||||||
|
|
Control Characteristics |
|
Ramp up : 0.5 to 5 sec. Bypass versions: .05 to 20 sec. Ramp down: 0.5 to 10 sec. Bypass versions 0.5 to 20 sec. Torque adjustment: 0-85% of nominal torque |
|
|
||||||
|
|
Oper. Temp. Range |
|
0° to +40°C: 100% load & duty cycle (Up to 60°C without derating) |
|
|
||||||
|
|
Mounting |
|
Vertical only (±30°) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|