A simple, passive product using two phases of a three-phase supply as input and a single-phase output. If one phase in interrupted, you still have clean constant power out of the RTD....Even if the remaining phase drops by a third.
This combination works perfectly since the heavy (motor, pump, conveyor, etc.) loads are not normally affected by power anomalies. So, a small RTD is only used to keep continuous single-phase power going to the more sensitive process controls.
|

|
Batteryless
|

|
Ideal for High Ambient Conditions (up to 50° C)
|
|

|
Maintenance-Free
|

|
Easy Installation
|
|

|
Surge Suppression
|

|
Power Conditioning
|
|

|
Overload Protection
|

|
Isolated Power
|
|

|
No Electronics
|
|
|
How the Ride Thru Device works...

|
|
Power Anomaly
|
Result
|
|
Loss of Phase A
|
Output remains constant
|
|
Loss of Phase B
|
Output remains constant
|
|
Loss of Phase C
|
Output remains constant
|
|
Loss of Phase A and B -
33% sag on remaining phase
|
Output remains constant
|
|
Loss of Phase B and C -
33% sag on remaining phase
|
Output remains constant
|
|
Loss of Phase A and C
|
Output goes to 0
|
|
Loss of A and 33% Sag on C
|
Output remains constant
|
|
Loss of C and 33% Sag on A
|
Output remains constant
|
|
37% Sag on A and C
|
Output remains constant
|
|
1.
|
Pick your two most trouble-free phases to feed the RTD Input
|
2.
|
Your Process Controls will receive constant, conditioned single phase power from the RTD output
|
|
EVEN WHEN: One of the two input phases is lost AND the remaining phase drops by 33%.
|
|
OR Both of the input phases experience a 33% drop in voltage
|
|
YOUR LOW-COST SOLUTION to "bulletproof" process controls normally susceptible to power variations which can bring down
an entire system...and it does it without batteries, electronics, static switches or an inverter!
|

|
Programmable Logic Controller (PLCs)
|

|
Graphic Interface Systems (GUI)
|

|
Process Upsets
|
|

|
Discrete Output (DO) Susceptibility
|

|
Relay Control Circuitry
|

|
False Negative Sensing
|
|

|
Injection Molding Machines
|

|
CNC Machines
|

|
Compressor Controls
|
|

|
Gas Valves
|

|
HVAC Controllers
|

|
Agitators
|
|

|
Pumps
|

|
Cooling Tower Fans
|

|
Elevator Drive Controllers
|
|

|
Chiller Controls
|

|
Motor Control Centers
|

|
Mixers
|
|

|
Batch Weighing
|

|
Furnaces
|

|
Batching Systems
|
|

|
Crushers
|

|
Conveyors
|

|
Robotic Welding Aplications
|
|

|
Photo Eye Emergency Stop Circuits (ESTOP)
|

|
High Intensity Discharge Lighting (HID)
|

|
Auxiliary Contact Applications
|
|

|
DC Power Supplies
|

|
Assembly Line Controls
|

|
Emergency Off Circuits (EMO)
|
|

|
Paint Booth Controls
|

|
Misinterpretation of IO Signals
|
|
|
|

|
"Ice Cube" Relays
|

|
Ready Circuit Kicks Machine Off
|
|
|
|
Over 60% of voltage sags involve only one phase. Two phases rarely sag at the same time
What this means is with a Ride Thru Device your process controls will hardly ever see any power disturbances (short of a complete three-phase power loss). Processes stay running during otherwise costly power variations.
|
Easy Installation
The RTD is wired in front of the existing control transformer in the machine. Since the Ride Thru Device is only protecting the process controls, a small 1 kVA model is normally sufficient. No need to oversize to accommodate heavy load inrush current demands. Model Selection? Simply pick your voltage input/output & load.
|
Power Conditioning
Unsurpassed protection from over voltage spikes and surges, brownouts and transient noise. Primary and Secondary are completely isolated, preventing noise from traveling back and forth either way.
|
|
|
Performance of PoweRide RTD and other typical Ride-Through Technologies
|
|
Technology
|
Sag Ride-through
|
Two Second Interruption
Ride-through
|
No Batteries
to Maintain
|
Useful for
Programmable
Controllers
|
Useful for Motor
Starters
|
Useful for Estop
Circuits
|
Use for Control Relays
|
Overall Score
0=Lowest
7-Highest
|
|
UPS
|
Yes
|
Yes
|
No
|
Yes
|
No
|
No
|
No
|
3
|
|
Batteryless UPS
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
No
|
No
|
5
|
|
Constant Voltage Transformer
|
Yes
|
No
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
6
|
|
Coil Hold in Device
|
Yes
|
No
|
Yes
|
No
|
Yes
|
Yes
|
Yes
|
5
|
|
PoweRide RTD
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
7
|
|