Jim D. Gray & Associates, Inc. - Distributing

CAGE NO. 4XGF3                          DUNS 178043733

PRESSURE TRANSDUCER

Differential pressure transducers- dry media

 

 

Applications

Static pressure in duct or room applications                

 

Variable air volume system

Filter status monitoring

 

Exceptional accuracy & stability

 

Improved tolerance to overpressure & vibration reduces field failures

High accuracy digital sensor maintains calibration

Circuit protection … prevents damage due to incorrect wiring

Monitors positive & negative pressure

 

 

 

 

972-699-9976

 

 

 

 

 

 

 

 

Part Number

Operating Range

Enclosure

Local Display

NIST

 

 

 

 

 

 

 

 

 

CXDLNO1S-C1

1" WC

Duct

YES

YES

 

 

CXDLXO1S-C1

1" WC

Duct

YES

NO

 

 

CXDXNO1S-C1

1" WC

Duct

NO

YES

 

 

CXDXXO1S-C1

1" WC

Duct

NO

NO

 

 

CXPLNO1S-C1

1" WC

Panel

YES

YES

 

 

CXPLXO1S-C1

1" WC

Panel

YES

NO

 

 

CXPXNO1S-C1

1" WC

Panel

NO

YES

 

 

CXPXXO1S-C1

1" WC

Panel

NO

NO

 

 

CXDLNO2S-C1

10" WC

Duct

YES

YES

 

 

CXDLXO2S-C1

10" WC

Duct

YES

NO

 

 

CXDXNO2S-C1

10" WC

Duct

NO

YES

 

 

CXDXXO2S-C1

10" WC

Duct

NO

NO

 

 

CXPLNO2S-C1

10" WC

Panel

YES

YES

 

 

CXPLXO2S-C1

10" WC

Panel

YES

NO

 

 

CXPXNO2S-C1

10" WC

Panel

NO

YES

 

 

CXPXXO2S-C1

10" WC

Panel

NO

NO

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

 

Media Compatibility

Dry air or inert gas

 

 

Input Power

 

12VDC-30VDC or 24VDC nominal

 

 

Output

 

Field selectable: 2-wire , loop powered 4-20mA, (clipped & capped), or 3-wire 0-5V/0-10V

 

 

Pressure Ranges:01

Unidirectional: 0.1/0.25/0.5/1.0"  WC F.S, jumper selectable

 

 

 

 

Bidirectional:±0.1, ±0.25, ±0.5, ±1.0 W.C. F.S. jumper selectable

 

 

Pressure Ranges:02

Unidirectional: 1.0/2.5/5.0/10.0"  W.C. F.S, jumper selectable

 

 

 

 

Bidirectional:±1.0, ±2.5, ±5.0, ±10.0 W.C. F.S. jumper selectable

 

 

Mode

 

Unidirectional or bidirectional jumper selectable

 

 

Display (option)

 

Signed 3-1/2 digit LCD, indicates pressure in inches of water column

 

 

Proof Pressure

 

3 psid

 

 

Burst Pressure

 

5 psid

 

 

Accuracy

 

±1% F.S. Combined linearity & hysteresis

 

 

Temperature effect

1" models: 0.05%/°C; 10" models 0.01%/°C (Relative to 25°C) to 50°C (32°F to 122°F)

 

 

Zero drift( 1 year)

 

1" models: 2.0% max.; 10" models: 0.5% max.

 

 

Zero adjust

 

Pushbutton auto-zero and digital input (2-pos terminal block)

 

 

Operating Environment

0°C to 60°C (32°F to 140°F); 0-90% RH non-condensing

 

 

Fittings

 

Brass barb; 1/8" o.d.

 

 

Physical

 

UL 94 V-0 Fire Retardant ABS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOME

ABOUT US

PRODUCT OVERVIEW

SERVICES

MANUFACTURERS

CONTACT US

NEWS

LINKS

GET A QUOTE