Electronic Overloads 0.3-80A Microprocessor based phase protection (phase loss / phase failure, phase current unbalance & phase reversal)
|
|
972-699-9976 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model No. |
Current setting range |
Number CT |
OC |
Phase Fail |
Stall |
Assym |
Rev. Phase |
Wiring |
Mounting Type |
Applied MC |
Trip Indicator |
Dimensions |
|
|
|
CRP22-2P |
0.3-1.5, 1-5, 4.4-22 |
2 |
|
น |
|
-- |
-- |
Tunnel |
Direct mount onto MC |
CRC-9, CRC-12, CRC-18, CRC-22 |
Red |
1.8" X 2.8" X 3.1" |
|
|
|
CRP22--2P (1a1b) |
0.3-1.5, 1-5, 4.4-22 |
2 |
|
|
|
-- |
-- |
Screw |
Separate Mount (screw or din-rail) |
Red / Grn |
2.1" X 3.1" X3.5" |
|
|
|
|
CRP22-3PR |
0.3-1.5, 1-5, 4.4-22 |
3 |
|
|
|
|
(3PR) |
Screw |
Red / Grn |
2.1" X 3.1" X3.5" |
|
||
|
|
CRP22-2S |
0.3-1.5, 1-5, 4.4-22 |
2 |
|
|
|
-- |
-- |
Screw |
Red |
2.1" X 2.7" X3.5" |
|
||
|
|
CRP22-3S/3SR |
0.3-1.5, 1-5, 4.4-22 |
3 |
|
|
|
|
(3SR) |
Screw |
Red / Grn |
2.1" X 2.7" X3.5" |
|
||
|
|
CRP22-2T |
0.3-1.5, 1-5, 4.4-22 |
2 |
|
|
|
-- |
-- |
Tunnel |
Direct mount onto MC |
Red |
2.1" X 1.5" X3.5" |
|
|
|
|
CRP22-3T/3TR |
0.3-1.5, 1-5, 4.4-22 |
3 |
|
|
|
|
(3TR) |
Tunnel |
Red / Grn |
2.1" X 1.5" X3.5" |
|
||
|
|
CRP40-2P |
4-20, 8-40 |
2 |
|
|
|
-- |
-- |
Tunnel |
CRC-32 CRC-40 |
Red |
3.5" X 3.1" X3.9" |
|
|
|
|
CRP40--3P/3PR |
4-20, 8-40 |
3 |
|
|
|
|
(3PR) |
Tunnel |
Red / Grn |
3.5" X 3.1" X3.9" |
|
||
|
|
CRP40-2S |
4-20, 8-40 |
2 |
|
|
|
-- |
-- |
Screw |
Separate Mount (screw or din-rail) |
Red |
2.1" X 2.7" X3.5" |
|
|
|
|
CRP40-3S/3SR |
4-20, 8-40 |
3 |
|
|
|
|
(3SR) |
Screw |
Red / Grn |
2.1" X 2.7" X3.5" |
|
||
|
|
CRP40-2T |
4-20, 8-40 |
2 |
|
|
|
-- |
-- |
Tunnel |
Red |
2.1" X 1.5" X3.5" |
|
||
|
|
CRP40-3T/3TR |
4-20, 8-40 |
3 |
|
|
|
|
(3TR) |
Tunnel |
Red / Grn |
2.1" X 1.5" X3.5" |
|
||
|
|
CRP80-2S |
16-80 |
2 |
|
|
|
-- |
-- |
Screw |
Direct/Separate mount (screw or din-rail) |
CRC-50 CRC-60 CRC-75 CRC-85 |
Red |
3.5" X 3.1" X3.9" |
|
|
|
CRP80-3S/3SR |
16-80 |
3 |
|
|
|
|
(3SR) |
Screw |
2 Red |
3.5" X 3.1" X3.9" |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation time |
|
Inverse time characteristics |
|
|
|
|
|
|
|
|
|
||
|
|
Control Power |
|
CRP22-2P (only): AC 90-250V (ฑ5%) |
ALL others: AC100-260V 50/60Hz |
|
|
|
|
||||||
|
|
Aux. Contact |
Contact |
CRP22-2P (only): 1SPST(1c)ฒ |
|
|
ALL others: 2SPST |
|
|
|
|
|
|||
|
|
Ratings |
CRP22-2P (only): 5A/250V resistive load |
ALL others: 3A/250VAC resistive load |
|
|
|
|
|||||||
|
|
Operate |
CRP22-2P (only): 95-96 N.N. |
|
|
ALL others: 95-96 N.C. 97-98 N.O. |
|
|
|
|
|||||
|
|
||||||||||||||