UNIVERSAL 60 BATTERY CHARGER / ANALYZER for rechargeable vented batteries (Nickel-Cadmium or Lead Acid) |
|
Jim D. Gray & Associates, Inc. |
|
Supporting O.E.M.’s since 1977 |
|
972-699-9976 |
|
Key Functions |
Constant Current Charge - provides constant current for specified time |
|
|
Dual Charge - two consecutive time periods with two separately specified constant current levels |
|
|
Constant Potential Charge - charges until battery voltage equals maximum voltage per cell X number of cells |
|
|
Constant Current Discharge - discharge at a specified current for a preset period of time to measure capacity |
|
|
Deep Discharge - can be performed by setting volts/cell below 1.0 with a low discharge current level |
|
Self-Calibration |
Self-Calibration for Current & Volts - allows technician to use a multimeter to calibrate the unit on the bench |
|
Accessories |
Battery Cable Assembly - connects battery being charged or analyzed with UNIVERSAL 60 with Elcon connector |
|
|
Cell Scanning Probe Set - Test probes for manually checking cell voltages |
|
|
SPECIFICATIONS |
|
Mechanical |
Dimensions: 18.5” X 21.5” X11”; Weight: 145 lbs; Case: Steel |
|
Electrical-Input |
187-265VAC single phase 47-63Hz; Current requirements 25A max. ; Power switch: opens both sides of line |
|
Electrical-Output |
Constant Current: 1 to 60A; Constant current discharge: 0.2 to 60A; Constant potential charge: 75V max. |
|
Electrical Displays |
Current: 99.9 full scale, accuracy ±2% of full scale; Voltage 99.9 full scale, accuracy ±2% of full scale: Individual Cells: 19.99 full scale, accuracy ±2% of full scale |
|
Environmental-Operating |
Ambient Temperature 0°-50°C; Altitude: 0 to 8000 feet; Designed to meet: EMI Mil-Std 460 & sand,dust Humidity of Mil-Std 810; CE compliant versions available |
|
Environmental-Storage |
Ambient temperature: 40°C to 71°C; Altitude: 0-50,000 feet |
|
|
|
|
|
|