
|
Jim D. Gray & Associates, Inc. - Distributing |
|
CAGE NO. 4XGF3 DUNS 178043733 |
|
UL489 MOLDED CASE CIRCUIT BREAKERS HVAC Rated 2-Pole Fixed Thermal & Magnetic 35kA UL interrupt @ 480VAC |
|
972-699-9976 |
|
|
|
|
CRH SERIES |
|
|
|
|
|
||||
|
|
2-Pole |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UL LISTED INTERRUPT RATINGS |
|
|
|
|
|||||
|
|
240V AC |
65kA |
|
|
|
|
|
|||
|
|
480V AC |
35kA |
|
|
|
|
|
|||
|
|
600V AC |
18kA (no rating for 100AF) |
|
|
|
|
|
|||
|
|
Model No |
LG Industrial Part No. |
FRAME SIZE |
AMP RATING (In) |
MAGNETIC TRIP SETTING |
|
|
|
|
|
|
|
CRH102U-15 |
ABH102U-15A |
100AF |
15 |
500A |
|
|
|
|
|
|
|
CRH102U-20 |
ABH102U-20A |
100AF |
20 |
500A |
|
|
|
|
|
|
|
CRH102U-30 |
ABH102U-30A |
100AF |
30 |
500A |
|
|
|
|
|
|
|
CRH102U-40 |
ABH102U-40A |
100AF |
40 |
500A |
|
|
|
|
|
|
|
CRH102U-50 |
ABH102U-50A |
100AF |
50 |
500A |
|
|
|
|
|
|
|
CRH102U-60 |
ABH102U-60A |
100AF |
60 |
600A |
|
|
|
|
|
|
|
CRH102U-80 |
ABH102U-80A |
100AF |
80 |
800A |
|
|
|
|
|
|
|
CRH102U-100 |
ABH102U-100A |
100AF |
100 |
1000A |
|
|
|
|
|
|
|
CRH202U-125 |
ABH202U-125A |
225AF |
125 |
5,6,7,8,9,10 X In (adjustable) |
|
|
|
|
|
|
|
CRH202U-150 |
ABH202U-150A |
225AF |
150 |
5,6,7,8,9,10 X In (adjustable) |
|
|
|
|
|
|
|
CRH202U-175 |
ABH202U-175A |
225AF |
175 |
5,6,7,8,9,10 X In (adjustable) |
|
|
|
|
|
|
|
CRH202U-200 |
ABH202U-200A |
225AF |
200 |
5,6,7,8,9,10 X In (adjustable) |
|
|
|
|
|
|
|
CRH202U-225 |
ABH202U-225A |
225AF |
225 |
5,6,7,8,9,10 X In (adjustable) |
|
|
|
|
|
|
|
CRH402U-250 |
ABH402U-250A |
400AF |
250 |
2500A |
|
|
|
|
|
|
|
CRH402U-300 |
ABH402U-300A |
400AF |
300 |
3000A |
|
|
|
|
|
|
|
CRH402U-350 |
ABH402U-350A |
400AF |
350 |
3500A |
|
|
|
|
|
|
|
CRH402U-400 |
ABH402U-400A |
400AF |
400 |
4000A |
|
|
|
|
|
|
|
CRH602U-500 |
ABH602U-500A |
600AF |
500 |
5000A |
|
|
|
|
|
|
|
CRH602U-600 |
ABH602U-600A |
600AF |
600 |
6000A |
|
|
|
|
|
|
|
UL magnetic trip setting tolerances are -20% and +30% from the nominal values shown |
|
|
|
||||||
|
|
100AF, 400AF & 600AF units have fixed thermal and magnetic over current device |
|
|
|
|
|
||||
|
|
225AF units have fixed thermal & adjustable magnetic over current device |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ACCESSORIES |
|
|
|
|
|
||||
|
|
Model No. |
Description |
|
|
|
|
|
|||
|
|
AX-225 |
Aux. contact for 100AF & 225AF |
|
|
|
|
|
|||
|
|
AX-600 |
Aux. contact for 400AF & 600AF |
|
|
|
|
|
|||
|
|
AL-225 |
Alarm switch for 100AF & 225AF |
|
|
|
|
|
|||
|
|
AL-600 |
Alarm switch for 400AF & 600AF |
|
|
|
|
|
|||
|
|
SHT-225 |
Shunt trip for 100AF & 225AF |
|
|
|
|
|
|||
|
|
SHT-600 |
Shunt trip for 400AF & 600AF |
|
|
|
|
|
|||
|
|
UVT-225 |
Under voltage trip for 100AF & 225AF |
|
|
|
|
|
|||
|
|
UVT-600 |
Under voltage trip for 400AF & 600AF |
|
|
|
|
|
|||
|
|
CI-23S |
Mechanical interlock for 100AF & 225AF |
|
|
|
|
|
|||
|
|
CI-43S |
Mechanical interlock for 400AF |
|
|
|
|
|
|||
|
|
CI-63S |
Mechanical interlock for 600AF |
|
|
|
|
|
|||
|
|
C-225S |
Handles/operators (NEMA 1) for 100AF & 225AF |
|
|
|
|
|
|||
|
|
C-400S |
Handles/operators (NEMA 1) for 400AF |
|
|
|
|
|
|||
|
|
C-600S |
Handles/operators (NEMA 1) for 600AF |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact Ratings for AX & AL auxiliary contacts |
|
|
|||||||
|
|
AC |
DC |
|
|
||||||
|
|
|
Max switching current |
|
|
Max switching current |
|
|
|||
|
|
Operational voltage |
Operational voltage |
|
|
|
|||||
|
|
|
Res. Load |
Ind. Load |
|
Res. Load |
Ind. Load |
|
|
||
|
|
125 |
|
5 |
3 |
30 |
|
4 |
3 |
|
|
|
|
230 |
|
3 |
2 |
125 |
|
0.4 |
0.4 |
|
|
|
|
-- |
|
-- |
-- |
250 |
|
0.2 |
0.2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage Ratings for Under Voltage Trip - UVT (All frames) |
|
|
|||||||
|
|
AC/DC Common |
24/48/100~110/200~220V |
|
|
||||||
|
|
DC |
380~440V, 440~480V |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage Ratings for Shunt Trip - SHT |
|
||||||||
|
|
|
|
|
|
100AF 225AF |
400AF 600AF |
|
|||
|
|
AC/DC Common |
|
|
24~48V |
|
|||||
|
|
12/24/48/60/250V |
AC200~240/DC200~220V |
|
|||||||
|
|
|
|
AC100~125/DC100~110V |
|
||||||
|
|
AC |
100~125/200~240V |
|
|
|
|
||||
|
|
380~450/440~480V |
380-460/480-550V |
|
|||||||
|
|
500~550V |
|
|
|
|
|||||
|
|
DC |
|
|
|
|
|
||||
|
|
100~110/125/200~220 |
--- |
|
|||||||
|
|
240/250 |
|
|
|
|
|||||
|
|
Operational voltage |
75-110% of rated volts |
|
75-110% of rated volts |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|