Jim D. Gray & Associates, Inc. - Distributing |
|
CAGE NO. 4XGF3 DUNS 178043733 |
|
972-699-9976 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Optional |
|
|
|
Part No. |
|
Motor Rating |
Output Ratings (380V based) |
Input Ratings |
|
|
Input Line Reactor |
|
|||||
|
|
|
|
HP |
kW |
kVA |
A |
Voltage |
Frequency |
Voltage |
Frequency |
Dimensions |
Weight |
P/N |
|
|
|
CI-000-GS2 |
|
0.5 |
0.4 |
0.95 |
2.5 |
3-Ø, 200-230V |
0~400 Hz |
3-Ø, 200-230V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 2.76" x 5.12" |
1.7 lbs |
LDRA54LC1 |
|
|
|
CI-001-GS2 |
|
1 |
0.75 |
1.9 |
5 |
3-Ø, 200-230V |
0~400 Hz |
3-Ø, 200-230V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 2.76" x 5.12" |
1.7 lbs |
LDRA25LC1 |
|
|
|
CI-002-GS2 |
|
2 |
1.5 |
3 |
8 |
3-Ø, 200-230V |
0~400 Hz |
3-Ø, 200-230V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 3.94" x 5.12" |
2.47 lbs |
LDRA27LC1 |
|
|
|
CI-003-GS2 |
|
3 |
2.2 |
4.5 |
12 |
3-Ø, 200-230V |
0~400 Hz |
3-Ø, 200-230V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 5.51" x 6.10" |
4.06 lbs |
LDRA28LC1 |
|
|
|
CI-005-GS2 |
|
5 |
3.7 |
6.1 |
16 |
3-Ø, 200-230V |
0~400 Hz |
3-Ø, 200-230V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 5.51" x 6.10" |
4.17 lbs |
LDRA22LC1 |
|
|
|
CI-000-GS4 |
|
0.5 |
0.4 |
0.95 |
1..25 |
3-Ø, 380-480V |
0~400 Hz |
3-Ø, 380-480V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 2.76" x 5.12" |
1.7 lbs |
LDRA6LC1 |
|
|
|
CI-001-GS4 |
|
1 |
0.75 |
1.9 |
2.5 |
3-Ø, 380-480V |
0~400 Hz |
3-Ø, 380-480V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 2.76" x 5.12" |
1.7 lbs |
LDRA8LC1 |
|
|
|
CI-002-GS4 |
|
2 |
1.5 |
3 |
4 |
3-Ø, 380-480V |
0~400 Hz |
3-Ø, 380-480V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 3.94" x 5.12" |
2.47 lbs |
LDRA1LC1 |
|
|
|
CI-003-GS4 |
|
3 |
23.2 |
4.5 |
6 |
3-Ø, 380-480V |
0~400 Hz |
3-Ø, 380-480V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 5.51" x 6.10" |
4.06 lbs |
LDRA2LC1 |
|
|
|
CI-005-GS4 |
|
5 |
3.7 |
6.1 |
8 |
3-Ø, 380-480V |
0~400 Hz |
3-Ø, 380-480V (+10%, -15%) |
50-60 Hz (±5%) |
5.04" X 5.51" x 6.10" |
4.17 lbs |
LDRA3LC1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OPTIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CI-NEMA1-GSA |
|
NEMA 1 Kit for CI-000-GS2. CI-001-GS2 |
|
|
|
|
|
|
|
||||
|
|
CI-NEMA1-GSB |
|
NEMA 1 Kit for CI-000-GS4. CI-001-GS4, CI-002-GS2, CI-002-GS4 |
|
|
|
|
|
|
|||||
|
|
CI-NEMA1-GSC |
|
NEMA 1 Kit for CI-003-GS2. CI-003-GS4, CI-005-GS2, CI-005-GS4 |
|
|
|
|
|
|
|||||
|
|
CI-RKPK-EXT2M-GS |
2 meter cable (remote mounting cable between inverter and keypad fixture |
|
|
|
|
|
|||||||
|
|
CI-RKPK-EXT2M-GS |
3 meter cable (remote mounting cable between inverter and keypad fixture |
|
|
|
|
|
|||||||
|
|
CI-RKPK-EXT2M-GS |
5 meter cable (remote mounting cable between inverter and keypad fixture |
|
|
|
|
|
|||||||
|
|
C Comm |
|
Modbus Communications card |
|
|
|
|
|
|
|
|
|||
|
|
NP |
|
Front mounted nameplate |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control Method |
|
Sensorless vector V/F control (Space vector PWM) |
|
|
|
|
||||
|
|
|
|
|
Freq. setting resolution |
Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over) Analog reference 0.03hz @ 50 Hz |
|
|
|||||||
|
|
|
|
|
Freq. setting accuracy |
Digital: 0.01% of maximum output frequency Analog: .1% of maximum output frequency |
|
|
|
||||||
|
|
|
|
|
V/F Ratio |
|
|
Linear Square User V/F |
|
|
|
|
|
||
|
|
|
|
|
Overload Capacity |
|
1 minute @ 150% 30 seconds @ 200% (with inverse characteristic proportional to time) |
|
|
|
|||||
|
|
|
|
|
Torque boost |
|
Auto Manual (0~15%) |
|
|
|
|
|
|||
|
|
|
|
|
Assigned Terminals |
|
FX (forward) RX (reverse) BX (inverter gate blocking) RST (reset) JOG (jog) |
|
|
|
|||||
|
|
|
|
|
Multi-function input terminals |
Total 3 inputs (programmable) |
|
|
|
|
|
||||
|
|
|
|
|
Analog output |
|
0~10V linear |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input Signal |
Operator control |
|
4 digits LED keypad Terminals ModBus communication |
|
|
|
|
||||||
|
|
Frequency setting |
|
Analog: 0~10V, 4-20mA Digital Keypad Communication: ModBus |
|
|
|
||||||||
|
|
Start signal |
|
|
Forward Reverse |
|
|
|
|
|
|||||
|
|
Multi-step operation |
|
Setting up to 8 speeds using multi-function terminals |
|
|
|
|
|||||||
|
|
Multi-step accel/decel time |
0.1~6000 seconds. Maximum 8 pre-defined steps using multi-funtion terminals |
|
|
|
|||||||||
|
|
Operation functions |
|
DC braking Frequency Limit Frequency Jump Second motor function Slip compensation Reverse rotation prevention |
|
||||||||||
|
|
|
|
|
|
Auto Restart PID controls |
|
|
|
|
|
||||
|
|
Emergency stop |
|
Interrupting output from inverter |
|
|
|
|
|
||||||
|
|
Jog |
|
|
|
Jog operation |
|
|
|
|
|
||||
|
|
Fault Reset |
|
|
Resets fault signal when protective function is active |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output signal |
Operational Status |
|
Frequency detection Overload alarm Stall Overvoltage Undervoltage Inverter overheat Run Stop Constant speed |
|
|||||||||
|
|
|
|
|
|
Speed search Fault output (relay and open collector output) |
|
|
|
|
|||||
|
|
Indicator |
|
|
Output frequency Output current Output voltage DC voltage RPM |
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Protective Functions |
Trip |
|
|
|
Overvoltage Undervoltage Overcurrent Inverter overheat Motor overheat I/O phase loss I/O miss wiring |
|
|||||||
|
|
|
|
|
|
Overload Speed command loss Hardware fault Communication error |
|
|
|
||||||
|
|
Alarm |
|
|
Stall Overload |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating environment |
Ambient Temp |
|
-10°~50°C |
|
|
|
|
|
|
||||
|
|
Storage Temp |
|
-20°~65°C |
|
|
|
|
|
|
|||||
|
|
Humidity |
|
|
90% RH max(non condensing) |
|
|
|
|
|
|||||
|
|
Altitude & vibration |
|
1000m max, 5.9m/sec²(0.6g)max. |
|
|
|
|
|
||||||
|
|
Application site |
|
No corrosive gas, flammable gas, oil mist or dust |
|
|
|
|
|||||||
|
|
|
|
|
Note* : Derating is required when carrier frequency is set avove 3kHz |
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|